KL-8052N

Pumping Mechanism                   Curvilinear peristaltic

IV Set                                           Compatible with IV sets of any standard

Flow Rate                                     0.1-1500 ml/h (in 0.1 ml/h increments)

Purge, Bolus                                 100-1500 ml/h (in 1 ml/h increments) Purge when

                                                         pump stops, bolus when pump starts

Bolus volume                               1-20 ml (in 1 ml increments)

Accuracy                                      ±3%

VTBI                                            1-9999 ml

Infusion Mod                                ml/h, drop/min, time-based

KVO Rate                                     0.1-5 ml/h (in 0.1 ml/h increments)

Alarms                                          Occlusion, air-in-line, door open, end program, low battery,

                                                              end battery, AC power off, motor malfunction, system

                                                              malfunction, reminder alarm

Additional Features                       Real-time infused volume / bolus rate / bolus volume/ KVO

                                                            rate, automatic power switching, mute key, purge, bolus,

 

Pumping Mechanism                   Curvilinear peristaltic

IV Set                                           Compatible with IV sets of any standard

Flow Rate                                     0.1-1500 ml/h (in 0.1 ml/h increments)

Purge, Bolus                                 100-1500 ml/h (in 1 ml/h increments) Purge when

                                                         pump stops, bolus when pump starts

Bolus volume                               1-20 ml (in 1 ml increments)

Accuracy                                      ±3%

VTBI                                            1-9999 ml

Infusion Mod                                ml/h, drop/min, time-based

KVO Rate                                     0.1-5 ml/h (in 0.1 ml/h increments)

Alarms                                          Occlusion, air-in-line, door open, end program, low battery,

                                                              end battery, AC power off, motor malfunction, system

                                                              malfunction, reminder alarm

Additional Features                       Real-time infused volume / bolus rate / bolus volume/ KVO

                                                            rate, automatic power switching, mute key, purge, bolus,